99久久香蕉国产线看观看

<dfn id="h3pb5"><noframes id="h3pb5">

    <output id="h3pb5"></output>

      <dfn id="h3pb5"><nobr id="h3pb5"><mark id="h3pb5"></mark></nobr></dfn>

      <listing id="h3pb5"><form id="h3pb5"></form></listing>
        我的購物車>> 中國區首家總代 專業十六載 打造細胞生物學精品
        ?
        您當前所在位置:首 頁 > 產品展示 > 細胞檢測試劑盒 > 細胞分析 小鼠端粒長度定量qPCR分析試劑盒(相對定量)RMTLQ

        小鼠端粒長度定量qPCR分析試劑盒(相對定量)RMTLQ

        英文名:Relative Mouse Telomere Length Quantification qPCR Assay Kit

        貨號:M8908

        價格:$108

        產品說明書下載:

        產品預訂,提交訂單信息之后,我們會第一時間與您取得聯系!

        Telomeres are repetitive nucleotide elements at the ends of chromosomes that protect chromosomes from degradation and genetic information loss. Normal diploid cells lose telomeres with each cell cycle. Telomere length, therefore, decreases over time and may predict lifespan. Telomere shortening has negative effects on health conditions and has been linked to many health issues including aging and cancer. Accurate and consistent quantification of telomere length is important in many aspects of cell biology such as chromosomal instability, DNA repair, senescence, apoptosis, cell dysfunctions, and oncogenesis.

        ScienCell's Relative Mouse Telomere Length Quantification qPCR Assay Kit (RMTLQ) is designed to directly compare the average telomere length of the samples. The telomere primer set recognizes and amplifies telomere sequences. The single copy reference (SCR) primer set recognizes and amplifies a 100 bp-long region on mouse chromosome 10, and serves as reference for data normalization. The carefully designed primers ensure: (i) high efficiency for trustworthy quantification; and (ii) no non-specific amplification. Each primer set has been validated by qPCR with melt curve analysis and gel electrophoresis for amplification specificity and by template serial dilution for amplification efficiency.

        貨號M8908
        產地美國
        縮寫RMTLQ
        規格100 reactions
        用途科研
        儲存-20度
        運輸干冰

        Question:

        There is a decrease in fluorescence that causes a decrease of the plateau phase (see the picture attached). What could be the cause?

        Answers:

        Dear Customer, thanks for contacting ScienCell!

        For some qPCR instruments, a Cq value (the number of cycles when a qPCR amplification can be first detected) lower than 15 may interfere with the default baseline settings, and will concomitantly cause the deviations in quantification. When that happens, we recommend using less gDNA per reaction (1-2 ng/reaction recommended, or contact the qPCR instrument manufacturer for changing the default baseline settings.

        Please do not hesitate to contact me if you need further assistance. I am at your service.

        Best regards,

        ScienCell Team

        相關產品
        貨號
        產品名稱
        規格
        價格
        指令
        聯系電話
        +86 10 63804220
        +86 10 63803739
        +86 10 63861816
        QQ客服
        99久久香蕉国产线看观看
        <dfn id="h3pb5"><noframes id="h3pb5">

          <output id="h3pb5"></output>

            <dfn id="h3pb5"><nobr id="h3pb5"><mark id="h3pb5"></mark></nobr></dfn>

            <listing id="h3pb5"><form id="h3pb5"></form></listing>